A Licensed Elevator Contractor is required to perform the work as follows:
A17.1-2019: Section 8.11.1.4 (b) Installation placed Out of Service
Section 8.11.1.4(b) (1) Electric elevator, dumbwaiter, or material lift whose suspension ropes have been removed, whose car and counterweight rest at the bottom of the hoistway, and whose hoistway doors have been permanently barricaded or sealed in the closed position on the hoistway side.
Section 8.11.1.4(b) (2) Hydraulic elevator, dumbwaiter, or material lift whose car rest at the bottom of the hoistway; when provided with suspension ropes and counterweight, the suspension ropes have been removed and the counterweight rest at the bottom of the hoistway; whose pressure piping has been disassembled and a section removed from the premises and whose hoistway doors are permanently barricaded or sealed in the closed position on the hoistway side:
Section 8.11.1.4(b) (3) Escalator or moving walk whose entrances have been permanently barricaded.